iHealth BG5 Smart Glucose Monitoring System with 10 Lancets Kit includes:
– iHealth Smart Gluco-Monitoring System (1 unit)
– iHealth Lancing Device (1 unit)
– Lancets (10 units)
– Clear Cap for Alternate Site Testing (1 unit)
– USB Charging Cable (1 unit)
– USB Charging Cable (1 unit)
– Travel Case (1 unit)
– Owner’s Manual (1 unit)
– Quick Start Guide (1 unit)
USES- : To monitor blood glucose level
KEY FEATURESÂ of iHealth BG5 Smart Glucose Monitoring System:
– Works wirelessly with user’s smartphone or tablet
– Measure blood glucose levels wirelessly from a mobile device
– View results in five seconds and save up to 500 results
– Set up reminders and view glucose and insulin trends in multiple ways
– Track test strip quantity and expiration date with a QR code automatically with no counting or coding required
– Logbook automatically records results in the app
– Sleek and portable design that is great for travelling
– Connects wirelessly via Bluetooth technology
– Free iHealth app includes personalized health tools
– Use only iHealth test strips
Extra KEY FEATURES- :
– Result range: 20 mg/dL ~600 mg/dL (1.1 mmol/L~33.3mmol/L)
– Blood source: Fresh capillary whole blood.
– Blood volume: Min. 0.7 microliter
INDICATIONS – :
Diabetes Mellitus
FAQ- ‘s about this item
QUESTION- – What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Details to the individual so that he can manage his blood glucose level on daily basis.
QUESTION- – Is this device reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
QUESTION- – How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
QUESTION- – What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is used before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
QUESTION- – Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
QUESTION- – How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
QUESTION- – How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
QUESTION- – Can I use one blood glucose test strip more than once?
It is recommended that always a new test strip should be used for the test.
QUESTION- – The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

Fair & Lovely Bb Cream 18 Gm for skin care
HealthyHey Panax Ginseng Extract 400mg Vegetable Capsules
Dabur Baby Super Pants Medium
ORSL Rehydrate Drink Orange 200ml_Johnson & Johnson Ltd
GARDEN OF LIFE Vitamin Code RAW B Complex 120 Vegan Capsules
Rossmax GD102 Palm BP Monitor
HIMALAYA Liv 52 DS Tablet
Vasu Giloy Ghanvati
HIMALAYA Litchi Shine Lip Care
Rex Barshasha Rex 60GM (U&A) Remedies Pvt. Ltd.
Shivalik Herbals Cheer-up 500mg Capsule
Jeevan shakti capsule for women
COMFREY Adult Diapers Large 10's Disposable Hip Size 40inches to 55inches
Fair & Lovely Cream 50G for skin care
Natures Velvet Lifecare Shatavari Pure Extract 500mg Capsule
Herbalifi Omega3 Fish Oil Capsules 1000mg with EPA and DHA Salmon Fish Oil Omega 3 Capsules for healthy heart and brain - 60 Counts for depression relieve
Shivalik Herbals Swet Musli- Asparagus 500mg Capsule
DOCTORS CHOICE Povidone Iodine Solution I.P 5% 500 Ml
Hamdard Safi Syrup 100ml
HIMALAYA Honey & Cream Soap PACK of 3
Bharat Spemento capsules
Naturyz Women's Fitness Daily Multivitamin with 55 Vital Nutrients 12 Performance Blends 60 Tablets
NOW FOODS MSM Pure Powder 8 ounce
Charak Aptizooom Syrup-Charak Pharma
Dremz Ultra Cream_Canixa Lifesci
Nutriherbs Organic Spirulina Super Food Capsules for Men & Women
HIMALAYA Oil Clear Mud Face PACK
Vinzyme tonic for digestion
HIMALAYA Wellness Pure Herbs Arjuna Cardiac Wellness Capsule
Charak Obenyl Tablet-Charak Pharma
Ponds Age Miracle Spf15 Cream 10Ml for skin care
HIMALAYA Anti Hair Fall Shampoo
MYPROTEIN Impact Whey Isolate Natural Chocolate 500GM
Equinox Pulse Oximeter EQ OP 108 

