iHealth BG5 Smart Glucose Monitoring System with 10 Lancets Kit includes:
– iHealth Smart Gluco-Monitoring System (1 unit)
– iHealth Lancing Device (1 unit)
– Lancets (10 units)
– Clear Cap for Alternate Site Testing (1 unit)
– USB Charging Cable (1 unit)
– USB Charging Cable (1 unit)
– Travel Case (1 unit)
– Owner’s Manual (1 unit)
– Quick Start Guide (1 unit)
USES- : To monitor blood glucose level
KEY FEATURESÂ of iHealth BG5 Smart Glucose Monitoring System:
– Works wirelessly with user’s smartphone or tablet
– Measure blood glucose levels wirelessly from a mobile device
– View results in five seconds and save up to 500 results
– Set up reminders and view glucose and insulin trends in multiple ways
– Track test strip quantity and expiration date with a QR code automatically with no counting or coding required
– Logbook automatically records results in the app
– Sleek and portable design that is great for travelling
– Connects wirelessly via Bluetooth technology
– Free iHealth app includes personalized health tools
– Use only iHealth test strips
Extra KEY FEATURES- :
– Result range: 20 mg/dL ~600 mg/dL (1.1 mmol/L~33.3mmol/L)
– Blood source: Fresh capillary whole blood.
– Blood volume: Min. 0.7 microliter
INDICATIONS – :
Diabetes Mellitus
FAQ- ‘s about this item
QUESTION- – What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Details to the individual so that he can manage his blood glucose level on daily basis.
QUESTION- – Is this device reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
QUESTION- – How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
QUESTION- – What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is used before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
QUESTION- – Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
QUESTION- – How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
QUESTION- – How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
QUESTION- – Can I use one blood glucose test strip more than once?
It is recommended that always a new test strip should be used for the test.
QUESTION- – The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

KERALA AYURVEDA Dhanwantharam Thailam oil
Calcarea Phosphorica Biochemic Tablet 6X- Dr Reckeweg & Co
HIMALAYA Wellness Combo PACK of Triphala and Bael Tablet
Folliserum Hair Growth Serum_ABBOTT
Happyglow Cream_Akumentis Healthcare
DAINIK CHURNA
Vasu Step Syrup
ZANDU Dashmoolarishta liquid
HIMALAYA Wellness Pure Hands Sanitizer Orange
HIMALAYA Koflet-SF Linctus PACK of 2
Acnedap Gel 15gm_Cipla
Titanic Extra Time Capsule by Mahamaya Drugs And Cosmetics Pvt Ltd
Alite Oil Control Gentle Face Wash 70gm-Leeford Healthcare Ltd
HIMALAYA Purifying Neem Face PACK
Mahanarayan Tail
Nestle Cerelac Baby Cereal Multigrain & Fruits Stage 4 300g
Pilinil tablet for piles
Natures Velvet Lifecare Jamun Pure Extract 500mg Capsule
Dabur Honey_DABUR INDIA
RHEUMINIL TABLET (for arthritis)
BAIDYANATH Pathrina Tablet Pack of 2
WOW Omega 3 1000mg capsules for healthy heart & joints
Homochek Capsule_Alkem labs
SRI SRI TATTVA Henna Shikakai Shampoo
ZANDU Tribangshila Tablet
Thioquest Gel-15GM-Alchem Phytoceuticals Ltd
NOW FOODS Iron 18 mg 120 Veg Capsules
KERALA AYURVEDA Aravindasavam syrup
Aruba Essentials Neem Oil for skin
Dabur Sitopaladi Churna_DABUR INDIA
HIMALAYA Wellness Pure Herbs Yashtimadhu Gastric Wellness Tablet
Aadar Jeevani Powder 100gm
Jeevan shakti capsule for women
Dabur Madhu Rakshak Powder_DABUR INDIA
KERALA AYURVEDA Manasamithravatakam Gulika tablet
Healthgenie BPM02 Upper Arm Digital BP Monitor 