iHealth BG5 Smart Glucose Monitoring System with 10 Lancets Kit includes:
– iHealth Smart Gluco-Monitoring System (1 unit)
– iHealth Lancing Device (1 unit)
– Lancets (10 units)
– Clear Cap for Alternate Site Testing (1 unit)
– USB Charging Cable (1 unit)
– USB Charging Cable (1 unit)
– Travel Case (1 unit)
– Owner’s Manual (1 unit)
– Quick Start Guide (1 unit)
USES- : To monitor blood glucose level
KEY FEATURESÂ of iHealth BG5 Smart Glucose Monitoring System:
– Works wirelessly with user’s smartphone or tablet
– Measure blood glucose levels wirelessly from a mobile device
– View results in five seconds and save up to 500 results
– Set up reminders and view glucose and insulin trends in multiple ways
– Track test strip quantity and expiration date with a QR code automatically with no counting or coding required
– Logbook automatically records results in the app
– Sleek and portable design that is great for travelling
– Connects wirelessly via Bluetooth technology
– Free iHealth app includes personalized health tools
– Use only iHealth test strips
Extra KEY FEATURES- :
– Result range: 20 mg/dL ~600 mg/dL (1.1 mmol/L~33.3mmol/L)
– Blood source: Fresh capillary whole blood.
– Blood volume: Min. 0.7 microliter
INDICATIONS – :
Diabetes Mellitus
FAQ- ‘s about this item
QUESTION- – What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Details to the individual so that he can manage his blood glucose level on daily basis.
QUESTION- – Is this device reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
QUESTION- – How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
QUESTION- – What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is used before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
QUESTION- – Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
QUESTION- – How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
QUESTION- – How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
QUESTION- – Can I use one blood glucose test strip more than once?
It is recommended that always a new test strip should be used for the test.
QUESTION- – The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

DABUR LAL TAIL 50 ML
MYPROTEIN LGlutamine Powder for Muscle Growth and Recovery 500GM
Microbenz 3.5% Gel_Sun Pharma
GARDEN OF LIFE Whole Food Probiotic Supplement Primal Defense ULTRA Ultimate Probiotic Formula Dietary Supplement 216 Vegetarian Capsules
Natures Way Neem Leaf 475 mg 100 Vegetarian Capsules
GARDEN OF LIFE Prenatal Gummy Vitamin with Folate mykind Organics Gummy Multivitamin for Women 120 Count Certified Organic Fruit Chews
SOURCE NATURALS CCM Calcium Citrate/Malate 60 Tabs
Similac Infant Formula Stage 1_ABBOTT
NOW FOODS Iron 18 mg 120 Vcaps
ASITIS Nutrition Whey Protein Isolate 1kg
Enshiner Ultra Cream 15gm-Leeford Healthcare Ltd
Dr Morepen Natural Collagen Builder Chocolate Powder_250gm
Telma CT 80/12.5 Tablet_GLENMARK PHARMA
Nutracology Calcium Advance Calcium citrate malate 1000mg with Magnesium vitamin D3 and zinc for strong bones for height growth
Natures Way Olive Leaf 100 Veg Capsules
JARROW FORMULAS Vitamin C 750 mg 100 Tablets
HIMALAYA Nourishing Skin Cream
Biluma Advance Skin Brightening Lotion 45gm_
NOW FOODS Vitamin D 3 5000 IU Structural Support Soft Gels 120 Count
Grd Swiss Chocolate Powder 400G
Swadeshi Triphala Aloevera Ras
Dr Ortho Combo of Pain Relief Oil 60ml & Pain Relief Spray 50ml
Natures Velvet Lifecare Womens Multivitamin Tablet
Romsons Ryles Tube FG 18 Pack of 4 