Details about Bayer Contour TS Blood Glucose Meter with Free 50 TS Blood Glucose Test Strip
Bayer Contour TS Blood Glucose Meter system delivers high performance in blood glucose monitoring.
The Contour TS is the perfect balance of advanced technology and simplicity for easy accuracy in test results.
USES- : To monitor blood glucose
Top KEY FEATURES- of Bayer Contour TS Blood Glucose Meter:
– Accurate result: Bayer’s no coding technology eliminates inaccuracies due to miscoding and accuracy can be seen across wide temperature range 5 – 45 degrees.
– More comfortable: Requires tiny blood sample size – 0.6µl and its Sip-In Sampling helps you get the right amount of blood on the first try
– Fast result: Bayer’s Contour TS deliver results within 8 seconds.
– Easy viewing: Has large LCD clear display with easy to see orange test strip port and simple two-button navigation.
Memory: H as 250 test memory and you can see your trends by looking at 7, 14 days Averages.
INDICATIONS – :
Diabetes Mellitus
FAQ- ‘s about this item
QUESTION- – What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Details to the individual so that he can manage his blood glucose level on daily basis.
QUESTION- – Is this device reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
QUESTION- – How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
QUESTION- – What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is used before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
QUESTION- – Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
QUESTION- – How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
QUESTION- – How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
QUESTION- – Can I use one blood glucose test strip more than once?
It is recommended that always a new test strip should be used for the test.
QUESTION- – The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

Vicco Turmeric Wso Skin Cream 30GM
Omron Hem 7121 BP Monitor
TYNOR Tummy Trimmer Abdominal Belt - Large
Cozyrich Q10 Tablet-10 Tablets-Leeford Healthcare Ltd
SRI SRI TATTVA Chyawanprash Pack of 2
BeSure Karela Juice
SRI SRI TATTVA Phalasarpi
Omron HEM 8711 BP Monitor
Axiom Aloevera Diabetes Cod 32 Juice-Axiom Ayurveda
JARROW FORMULAS Glutathione Reduced 500 mg 60 Veggie Caps
Kamasutra Superthin Condom_ 12 condoms
Natures velvet Lifecare Multivitamins Minerals and Antioxidants Tablet for Overall Health (60 Tablets)
TYNOR Ash Brace (Hyper Extension Brace) - Small
Zenith Nutrition Green Tea Plus 500mg Capsule
SRI SRI TATTVA Maha Triphaladya Ghrita
V Total Syrup_Aristo Pharma
Dynapar MR Tablet_TROIKAA
Farmity Keto Advanced Weight Loss Supplement (With CLA 60%) Sustained Energy & Boost Metabolism, 60 Capsules (800 Mg) for obesity
Simply Nutra Korean Ginseng Veg Capsule
Calcigen D3 Capsule_Cadila Pharma
TYNOR Universal Shoulder Child Immobilizer (Gray)
TYNOR TYA-09A Special Size Rib Belt
Al Shams Eye Drop-Satya Pharmaceuticals
Opexa Advanced Scar Treatment Gel 10gm-Ajanta Pharma Ltd
Venus Digital LCD Weighing Scale Purple Glass
Rossmax GD102 Palm BP Monitor
Neuherbs Red Wine Cider Vinegar with Mother
CENTRUM Multivitamin Women 50 Plus 30 Tablets
FLAMINGO HC-1010 Cool Pack L
Durex Extra Ribbed Condom_ 10 condoms
3M Littmann Classic II Pediatric Stethoscope, Caribbean Blue Tube, 28 inch, 2119
ZENITH NUTRITION Astaxanthin 4mg (30Caps)
TYNOR Knee Cap Open Patella - Medium
Neuherbs Apple Cider Vinegar Honey with the Mother
Neuherbs Probiotics with Added Prebiotics Veggie Caps
Dabur Glucoplus C Powder Lemon_DABUR INDIA
Dr Morepen MT 111 Digi Classic Digital Thermometer
Dr Ortho Pain Relief Patch 5 patches
Smart Care Crepe Bandage Premium 6cm*4Mtr
Healthvit Vitamin B6 25 mg 60 Capsules
Dr Gene Accusure TK Automatic BP Monitor 