Details about Bayer Contour TS Blood Glucose Meter with Free 50 TS Blood Glucose Test Strip
Bayer Contour TS Blood Glucose Meter system delivers high performance in blood glucose monitoring.
The Contour TS is the perfect balance of advanced technology and simplicity for easy accuracy in test results.
USES- : To monitor blood glucose
Top KEY FEATURES- of Bayer Contour TS Blood Glucose Meter:
– Accurate result: Bayer’s no coding technology eliminates inaccuracies due to miscoding and accuracy can be seen across wide temperature range 5 – 45 degrees.
– More comfortable: Requires tiny blood sample size – 0.6µl and its Sip-In Sampling helps you get the right amount of blood on the first try
– Fast result: Bayer’s Contour TS deliver results within 8 seconds.
– Easy viewing: Has large LCD clear display with easy to see orange test strip port and simple two-button navigation.
Memory: H as 250 test memory and you can see your trends by looking at 7, 14 days Averages.
INDICATIONS – :
Diabetes Mellitus
FAQ- ‘s about this item
QUESTION- – What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Details to the individual so that he can manage his blood glucose level on daily basis.
QUESTION- – Is this device reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
QUESTION- – How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
QUESTION- – What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is used before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
QUESTION- – Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
QUESTION- – How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
QUESTION- – How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
QUESTION- – Can I use one blood glucose test strip more than once?
It is recommended that always a new test strip should be used for the test.
QUESTION- – The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

HealthVit Guggul 250mg Capsule Pack of 2
Infomed Optima Cast 4 inch
Elanor Warm Bag
Romsons Ryle`s Tube FG 14 Pack of 4
GARDEN OF LIFE Primal Defense 90 Caplets
Bajaj Nomarks Ayurvedic Antimarks Cream Normal Skin_Bajaj Corp Ltd
Dr Ortho Pain Relief Spray 50ml spray
TYNOR Baggy Pouch Arm Sling - Medium
RAJOCAPS TABLET
Abhay MEDARI Slim Fit Tablets Weight Loss Supplement and Effective Fatrid (60 Tablets) for obesity
Mama Protinex Chocolate Powder 250gm_Nutricia International
CENTRUM Women MultiGummies Multivitamin/Multimineral Supplement (Natural Cherry Berry & Orange Flavor 70 Count Gummies)
Asthalin Rotacaps 60 capsules_Cipla
HealthVit Glucosar Forte Tablet
Combihale FF CFC Free 250 Inhaler 120 MDI Inhaler
3M Littmann Classic III Monitoring 27 inch Stethoscope (Black Tube)
Venus Digital LCD Weighing Scale SS Steel
DOCTORS CHOICE Knee Support Regular Large
Dr Ortho Combo of Pain Relief Oil 60ml & Pain Relief Crepe Bandage (8X4)
Dr Morepen MT 100 Digi Classic Thermometer
JARROW FORMULAS L Carnosine Beta Alanyl L Histidine 1000 mg 90 Capsules
KERALA AYURVEDA Kesini Oil
DOCTORS CHOICE Absorbent Cotton wool I.P. 400 gm
Allen Hymusa Tonic
MYPROTEIN Impact Whey Isolate Chocolate Smooth 500GM
DIVISA HERBAL CARE Lime & Aloevera Soap-DIVISA HERBAL CARE
Equinox Personal Digital Weighing Scale EQ EB 90
DOCTORS CHOICE Lumbar Sacro Support Xl
Lulilok Soap 50gm-Oaknet Healthcare Pvt Ltd
Romsons Urometer 