Detail about Bayer Contour Plus Glucometer with Free 50 Test Strip
Bayer Contour Plus Glucometer offers remarkable accuracy & easy to Its used features like second chance sampling, basic & advanced modes (L1/L2).
Its used: To check blood glucose level
Main Functions of Bayer Contour Plus Glucometer:
– Blood sample size: Requires tiny blood sample size of 0.6µl.
– Easy viewing: Has large LCD clear display which is easy to read.
– Fast Results: Bayer’s Contour Plus deliver results within 5 seconds.
– Smart technology: It has following two modes:
a) Basic Mode (L-1): Gives 7 days High and Low summary and 14-day average with 480 test result memory.
b) Advanced Mode (L-2): Gives 7 day high and low summary and 7, 14, and 30-day averages with 480 test result memory.
– More Comfortable: Shows pre- and post-meal markers with 30-day. Post-meal reminders 2, 5; 2, 0; 1, 5; 1, 0 hours can also be selected
INDICATION
Diabetes Mellitus
FAQ About this item
Question- What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Detail to the individual so that he can manage his blood glucose level on daily basis.
Question- Is Bayer Contour Plus Glucometer reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
Question- How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
Question- What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is Its usedd before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
Question- Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
Question- How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
Question- How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
Question- Can I Its used one blood glucose test strip more than once?
It is recommended that always a new test strip should be Its usedd for the test.
Question- The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

KERALA AYURVEDA Kachooradi Choornam Pack of 2 powder
Shivalik Herbals Shilajeet- Asphaltum 500mg Capsule
i pill Tablet_Piramal healthcare
Nestle Cerelac Rice Stage1 300G
SBL Dibonil Drop-30ml-SBL Pvt Ltd
Lite HORLICKS Regular Malt Jar 500g
Hansaplast Jumbo Antiseptic Larger Wound Pad 10 STRIPS
Arokleen Adult Diaper M
Enerzal Powder Lime-Fdc
Evion 200mg Capsule_Procter & Gamble Hygiene and Health Care Ltd
CLINSOL PLUS GEL 15gm_Leeford healthcare
Astymin Forte Capsule_Tablets India Limited
Hamdard Majun Dabidulward paste
Baidyanath Sarswatarista 450ml
Depiwhite Masque
Dr Odin MT 4320 Digital Thermometer
Fraink Figura Plus Capsule
Ayapon Tablet_Alarsin Pharma
Vasu Zeal Cough Syrup
Hansaplast Spot 50 band aids
Ponds Pure White Facial Foam 100G for skin care
Diapo Adult Diaper L
Sandu Shatari Granules 200gm
Speaking Tree Lemon Grass Essential Oil
Sebamed Baby Body Milk Lotion_USV Ltd
Vasu Ranger Capsule
Fair & Lovely Winter Fairness Cream 25gm for skin care
Niargim Tablet_AVN
Sebamed Baby Wash Extra Soft_USV Ltd
Himalayan Organics Melatonin 10mg (Healthy Sleep Cycle) - 120 Tablets (120) for depression relieve
Dabur Shilajit Gold Capsule (10 Capsules)
Novoret Neo Softgel_10 softgel
Fit shadow Starpro Sugar free Whey Protein Concentrate (Chocolate 4 Kg/8 8 Lbs)
Winlip Health tone Herbal Weight Gain Capsules for weight gain
Trichup Keratin Hair Conditioner
AVN MANDOORA VATAKAM TABLET
HIMALAYA Strawberry Shine Lip Care
Vigomax Forte Tablet-Charak Pharma
Vaseline Blue Seal Men Cooling Petroleum Jelly 100ml for skin care
Natures Way Slippery Elm Bark 400 mg 100 Veggie Caps
Vasu Face Mask Skin Purifying
CORDIT CAPSULE (for heart problems)
Equinox EQ BR 9201 Personal Weighing Scal
Omron Hem 7200 AP3(Jpn1) BP Monitor-Omron Healthcare 