Bayer Contour Plus Glucometer offers remarkable accuracy & easy to Its used features like second chance sampling, basic & advanced modes (L1/L2).
Its used: To check blood glucose level
Main Functions of Bayer Contour Plus Glucometer:
– Blood sample size: Requires tiny blood sample size of 0.6µl.
– Easy viewing: Has large LCD clear display which is easy to read.
– Fast Results: Bayer’s Contour Plus deliver results within 5 seconds.
– Smart technology: It has following two modes:
a) Basic Mode (L-1): Gives 7 days High and Low summary and 14-day average with 480 test result memory.
b) Advanced Mode (L-2): Gives 7 day high and low summary and 7, 14, and 30-day averages with 480 test result memory.
– More Comfortable: Shows pre- and post-meal markers with 30-day. Post-meal reminders 2, 5; 2, 0; 1, 5; 1, 0 hours can also be selected
INDICATION
Diabetes Mellitus
FAQ About this item
Question- What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Detail to the individual so that he can manage his blood glucose level on daily basis.
Question- Is Bayer Contour Plus Glucometer reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
Question- How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
Question- What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is Its usedd before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
Question- Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
Question- How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
Question- How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
Question- Can I Its used one blood glucose test strip more than once?
It is recommended that always a new test strip should be Its usedd for the test.
Question- The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

Dr Morepen BP 02 Blood Pressure Monitor
Matrix Nutrition Real Mass Chocolate
ORGANIC INDIA Saffron Threads
Dr. Gene Accusure 1.5V Pulse Oximeter Device-Microgene Diagnostic Systems
Tigboderm RF Cream 5gm_NEM LABS
CENTRUM Silver Women 50 Plus Multivitamins 275 Tabs
DOVE Fresh Moisture Soap 75G
APL Straight Hand Piece
BD Emerald 5ml Syringe
Rossmax HC700 Non Contact Telephoto Thermometer
Zabesta 2.5 Tablet_USV Ltd
BAIDYANATH Basant Kusumakar Ras with Gold, Silver & Pearl tablets(50)
Dabur Abhayarishta_DABUR INDIA
Hindustan Ayurveda Speed Growth | Vanilla Flavor 100GMs Powder (Pack Of 3) for height growth
Dabur Mahanarayan Tail 50ml
California Baby Natural Bug Repellent Spray 2 FL OZ(59 ML)
Vaseline Healthy white for skin care
Hamdard Chandraprabha Wati tablet
Diabetrol Tablet_ABBOTT
HIMALAYA Men Active Sports Face Wash
Phi Naturals Ashwagandha Organic Herbal Supplement 500mg 90 Capsules for thyroid
Pond's Pure White Anti Pollution Activated Charcoal Face Wash 200gm
Charak Moha Soap-Charak Pharma
Omron HN 286 Digital Weighing Scale
Infomed Fine POP 15cm Plaster
Arjunin Capsule-Charak Pharma
Cypon H Plus Syrup_Geno Pharma
Dabur Lavanbhaskar Churna 2 qty per pack_DABUR INDIA
Romsons Ryle`s Tube FG 14 Pack of 4
Nurokind More Tablet_MANKIND PHARMA
PediaSure Refill Pack Premium Chocolate_ABBOTT
Himalaya Abana Tablet 60 tablets
Pulse Wave Cardiac I SS Stethoscope Black 