Detail about Bayer Contour Plus Glucometer with Free 50 Test Strip
Bayer Contour Plus Glucometer offers remarkable accuracy & easy to Its used features like second chance sampling, basic & advanced modes (L1/L2).
Its used: To check blood glucose level
Main Functions of Bayer Contour Plus Glucometer:
– Blood sample size: Requires tiny blood sample size of 0.6µl.
– Easy viewing: Has large LCD clear display which is easy to read.
– Fast Results: Bayer’s Contour Plus deliver results within 5 seconds.
– Smart technology: It has following two modes:
a) Basic Mode (L-1): Gives 7 days High and Low summary and 14-day average with 480 test result memory.
b) Advanced Mode (L-2): Gives 7 day high and low summary and 7, 14, and 30-day averages with 480 test result memory.
– More Comfortable: Shows pre- and post-meal markers with 30-day. Post-meal reminders 2, 5; 2, 0; 1, 5; 1, 0 hours can also be selected
INDICATION
Diabetes Mellitus
FAQ About this item
Question- What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Detail to the individual so that he can manage his blood glucose level on daily basis.
Question- Is Bayer Contour Plus Glucometer reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
Question- How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
Question- What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is Its usedd before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
Question- Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
Question- How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
Question- How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
Question- Can I Its used one blood glucose test strip more than once?
It is recommended that always a new test strip should be Its usedd for the test.
Question- The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

Sinew Nutrition CURCUMIN WITH PIPERINE EXTRACT Capsule
TYNOR Neoprene Hinged Knee Support - Large (Grey)
Gefticip 250 mg Tablet_CIPLA
Roff Gel_Unichem Labs
Clitty Clitty Bang Bang Mini Stroker
Celcox 200 mg Capsule_LUPIN
Purepassion Imported Man's Organ Pump With Free Ring Accessories
SRI SRI TATTVA Narayana Taila
HealthVit Magnesium Orotate 500mg Tablet
GNC Womens Ultra Mega Heart Caplet
ORSL Rehydrate Drink Orange 200ml_Johnson & Johnson Ltd
ORGANIC INDIA Moringa Capsule
Cuticolor Hair Coloring Cream Dark Brown-ZYDUS CADILA
Efatop PE Cream 60GM-Oaknet Healthcare Pvt Ltd
New Accu Chek Instant S Blood Glucose Meter
Peptamen Junior Peptide Based Diet Powder-400gm-Nestle India Ltd
Dr Odin B12 Fully Automatic Digital Blood Pressure Monitor
Morpheme Mind Plus Capsule_Morpheme Remedies
Easy Bed Anti Decubitis Air Pump Mattress
Romsons Aero Mist Nebulizer Adult Mask
JARROW FORMULAS L Glutamine 750 mg 120 Capsules
Minscalp F Max Solution-60 ml -East West Pharma
Cilnikem 5 mg Tablet_ALKEM LABS
KERALA AYURVEDA Kutajarishtam syrup
Ibugesic Plus 400mg/325mg Tablet_CIPLA
Folirich Hair Growth Serum_Regaliz India
Pulse Wave Standard Stethoscope Black
ZANDUzyme Tablet
Arbitel 20 mg Tablet_MICRO LABS
Dr Gene Accusure 15V Pulse Oximeter Device 