Detail about Bayer Contour Plus Glucometer with Free 50 Test Strip
Bayer Contour Plus Glucometer offers remarkable accuracy & easy to Its used features like second chance sampling, basic & advanced modes (L1/L2).
Its used: To check blood glucose level
Main Functions of Bayer Contour Plus Glucometer:
– Blood sample size: Requires tiny blood sample size of 0.6µl.
– Easy viewing: Has large LCD clear display which is easy to read.
– Fast Results: Bayer’s Contour Plus deliver results within 5 seconds.
– Smart technology: It has following two modes:
a) Basic Mode (L-1): Gives 7 days High and Low summary and 14-day average with 480 test result memory.
b) Advanced Mode (L-2): Gives 7 day high and low summary and 7, 14, and 30-day averages with 480 test result memory.
– More Comfortable: Shows pre- and post-meal markers with 30-day. Post-meal reminders 2, 5; 2, 0; 1, 5; 1, 0 hours can also be selected
INDICATION
Diabetes Mellitus
FAQ About this item
Question- What is the need to monitor blood glucose (blood sugar) level in the body?
Monitoring blood glucose level is important since it gives a valuable Detail to the individual so that he can manage his blood glucose level on daily basis.
Question- Is Bayer Contour Plus Glucometer reliable for self-monitoring of blood glucose level?
Yes, this device is reliable for self-monitoring of blood glucose level in the body. The range of internationally accepted standard error for blood sugar values estimated by glucometer is 10-15% i.e about 10mg/dl up or down from standard value.
Question- How do I check whether the glucometer is calibrated or not?
Usually, the glucose test strip comes with a unique code so the first step should be to turn the meter on and check whether the code on the test strip and that on the glucometer is same. If codes do not match it indicates that the glucometer is not calibrated.
Question- What is the general procedure for calibrating any glucometer either automatic or manually?
If the code mentioned on the test strip does not match with the code mentioned on the glucometer then it should be calibrated using the following procedure:
1) Meter with Manual Calibration:
– If the meter is Its usedd before then there will be a coding number. See the code number on the test strip label and insert the strip in the meter and enter the code number in the meter by moving the ‘up’ or ‘down’ arrow to calibrate it.
– If the glucometer is new, instead of a coding number, there will be dashes.
2) Meter with Automatic Calibration:
– Turn on the blood glucose meter by pressing the power button
– Open the meter and insert the test strip and close it
– Then the meter will now be calibrated
Question- Is there any difference between checking blood glucose using a glucometer and from a lab?
The glucometer value gives an estimate of blood sugar in capillary blood while the lab value gives an estimate of blood sugar in the venous blood. In capillary blood, the amount of glucose is less as compared to the venous blood so the difference is slightly elevated for a glucometer reading.
Question- How frequently should a diabetic patient test his blood sugar in case of other diseased conditions like any infection, fever etc?
In a diabetic patient, such problems may get complicated easily, in that case, the anti-diabetic regimen should not be discontinued. Blood glucose level should be tested more often and if serious problems like recurrent vomiting, problem in taking food orally or unstable blood glucose level (high or less than 70mg/dl) starts to occur then immediately visit a doctor.
Question- How frequently should I monitor the increased dose of drug/insulin by the doctor?
After an increased dose, the monitoring should be done more frequently to avoid facing any critical situation. Especially in case of new drug initiation or multi-drug therapy with insulin.
Question- Can I Its used one blood glucose test strip more than once?
It is recommended that always a new test strip should be Its usedd for the test.
Question- The battery of glucometer can be charged or need to be replaced?
The battery of the glucometer needs to be replaced.

Ensure Plus Powder Vanilla_ABBOTT
P Glitz 15 mg Tablet_CIPLA
Macbrite D3 Soft Gelatin Capsule_Macleods Pharma
Lisoril 5 HT Tablet_IPCA LABS
Relcer Oral Gel_GLENMARK
Enapril 5 mg Tablet_INTAS
Glucored Forte SR Tablet_SUN PHARMA
California Baby California Kids Superclear Face Wash 2.9 OZ-82 GM
D2D Tablet_Alarsin Pharma
St.Botanica 24K Gold Face Mask for skin
Nutriherbs Guggul Extract Capsule_Skygain Nutricare
MuscleXP Green Coffee Bean Ultra Lean Vital Capsule (Pack OF 3)
Flabgo Garcinia Cambogia & Green Coffee Extracts Capsule
Nexovas 5 mg Tablet_MACLEODS PHARMA
Terbiderm Cream_SUN PHARMA
St.Botanica 24K Gold Face Scrub for skin
Lemo Oral Drops_YASH PHARMA
Nasomist Nasal Spray 20ml-Meridian Enterprises Pvt Ltd
Naturals Fit Pure & Natural Arabica Green Coffee Beans for Weight Loss_Fat Burner Supports Metabolism for Weight Management & Fat Burn 200gm for obesity
Bharat Til Oil
Omron NE C28 C1 Nebuliser
Festive Dee Optic Eye/Ear Drops 10ml_Laborate Pharmaceuticals India Ltd
SRI SRI TATTVA Aloe Vera Triphala Juice
Aten 100 mg Tablet_ZYDUS CADILA
Aldigesic P 100 mg/500 mg Tablet_ALKEM LABS
16 Again Raw Shilajit_Skygain Nutricare
Ensure Diabetes Care Powder Vanilla delight-Abbott
FIT SHADOW Extream Weight Gainer Mass Gainer High Protein Supplement Powder 3kg/6.6lbs (Sugar free) Best Weight Gainer For Men boys Womens Beginners,Low Fat,Low Carb (Cream & cookies) for weight gain
Heine Mini 3000 Ophthalmoscope with Xenon Halogen Technology 

